CHERNE -  Air Loc® Manhole Vacuum Testing Equipment

BACK          CHERNE MAIN PRODUCTS PAGE       PLUG SAFETY               CHERNE PLUMBING PRODUCTS              

CHERNE Manhole Vacuum Test Plate Style
Plate Style Manhole Vacuum Test
CHERNE Manhole Vacuum Test Bladder Style
Bladder Style Manhole Vacuum Test
Air-Loc® Manhole Testers provide the most efficient, accurate, and cost effective method of testing new, existing, and rehabilitated manholes. Vacuum testing identifies infiltration and exfiltration problems. The Air-Loc manhole testing system allows you to test manholes within minutes. It provides immediate leak detection, before or after ring installation and backfilling, while also eliminating expensive/time-consuming water tests. Manhole testing is performed by creating a vacuum in the manhole and monitoring a gauge for vacuum loss. The head assemblies are made of lightweight aluminum, making them the lightest units available.

CHERNE Manhole Vacumm Plate and Bladder Style Illustration

Plate Style - Seals from or top of cone. Works great if manhole is exposed or before backfilled.
MOST POPULAR STYLE
Bladder Style - Seals inside the frame and above or below grading rings. Works well on both existing and newly installed manholes.
 
Air-Loc Manhole Testers conform to ASTM Specification C1244 Standard Test for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test and ASTM C1227 Standard Test for Pre-cast Concrete Septic Tanks.
CHERNE Venturi Manhole Vacuum Tester with Plate
Vacuum Generator with Plate
CHERNE Venturi01 Vacuum Tester for Manholes
Vacuum Generator
The Air-Loc Vacuum Generator* allows vacuum testing of a manhole without the use of a separate vacuum pump. This device turns your standard air compressor into a vacuum generator for testing manholes. Simply attach the unit to a head assembly and an air compressor to draw a vacuum in minutes. Using a 100 PSI air compressor with a minimum output of 7 CFM, the Cherne Vacuum Generator draws up to 9 CFM at 10" hg. The Vacuum Generator draws 10" hg vacuum in a 10" manhole in approximately 3 minutes, while a the vacuum pump draws 10? hg vacuum in approximately 2 minutes.

Manhole Vacuum Test Procedure to Locate leaks

Soapy Bubble Leak Detection Test- Manhole testing is performed by creating a vacuum in the manhole and monitoring a gauge for vacuum loss. If a loss does occur, there is a simple way to locate the leak. You simply pour soapy water on the inside walls of the manhole, draw another vacuum and then look for the bubbles and you have identified the location of your leak.
 